Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2019, 08:43 AM
  • 05 2311_05 2310 _12052019_010047.mp4

Date
12/05/2019
W/O
798297
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00462
PipeID
P07433
Time
12:43 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6351
Sewer Name
05 INGLEWOOD TRUNK #1 RELIEF
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_798297_TV05326_NOV2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 2311
Downstream MH
05 2310
Dir. of Survey
Downstream
Length Surveyed
505 ft.
Total Length
505 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 05 2311 to 05 2310
MH: 05 2311MH: 05 2310downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 23110 ft. MWM - Water Mark, 25 %of cross sectional area88.4 ft. FC - Fracture Circumferential, from 03 to 06 o'clock, within 8 inches of joint: YES505 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK505 ft. AMH - Downstream Manhole, Survey Ends - 05 2310

Observation photos (1)

  • Fracture Circumferential, from 03 to 06 o'clock, within 8 inches of joint: YES

    88.4 ft. - Fracture Circumferential, from 03 to 06 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
88.4FC
505MGOCONNECTION AT MH 9 O'CLOCK
0MWL
0AMH05 2311
0MWM
505AMH05 2310

Properties (7)

additional_info
SC365794
custom_field_two
3
customer
LACSD
datetime
2019-12-05T00:43:33-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
30643