11_1_2_18122019_022240.mp4
2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
12.3 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
12.3 ft. - General Observation - 20% OLD MAG COAT
70.5 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
92 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR
92 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
96.3 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
96.6 ft. - General Photograph - CIRCUM REBAR
158.7 ft. - General Observation - RUST ON CONCRETE THROUGHOUT REACH
293.4 ft. - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 99.9 | SRV | CIRCUM REBAR |
| 79.3 | SRV | CIRCUM REBAR |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 239.2 | TFC | STUB |
| 0 | AMH | 2:20AM |
| 0 | MWL | — |
| 142 | TFC | STUB |
| 92 | SRV | LONG REBAR |
| 0 | MWM | — |
| 232.7 | TFC | STUB |
| 293.4 | SAV | CIRCUM REBAR |
| 93.8 | TFC | STUB |
| 12.3 | SAV | SEVERE AGG SPORATIC |
| 45.9 | TFC | STUB |
| 12.3 | MGO | 20% OLD MAG COAT |
| 96.6 | MGP | CIRCUM REBAR |
| 334.1 | SSS | BLISTERING PEELING CONCRETE |
| 2 | SAV | SEVERE AGG SPORATIC |
| 334.8 | AMH | 2:55AM |
| 70.5 | SRV | CIRCUM REBAR |
| 2 | MGO | MH CONN 3:00 ACTIVE |
| 296.4 | TF | OPEN |
| 92 | SRV | CIRCUM REBAR |
| 158.7 | MGO | RUST ON CONCRETE THROUGHOUT REACH |
| 96.3 | SRV | CIRCUM REBAR |
| 334.1 | SAV | BLISTERING PEELING CONCRETE |