Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2019, 08:21 AM
  • 9_1_3_18122019_002716.mp4

Date
12/18/2019
W/O
0807676
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00282
PipeID
P03664
Time
12:21 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0301
Sewer Name
02 MONTEBELLO DIVERSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
20191216MDM_MONTEBELLO_DIVERSION_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 1089
Downstream MH
02 1090
Dir. of Survey
Upstream
Length Surveyed
117.8 ft.
Total Length
117.8 ft.
Structural Index
3
Structural Quick
3D2D
Structural Rating
118
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
118
Pipe schematic from manhole 02 1089 to 02 1090
MH: 02 1089MH: 02 1090upstream0 ft. AMH - Upstream Manhole, Survey Ends(COMPLETED BY REVERSE INSPECTION) - 12:45AM(COMPLETED BY REVERSE INSPECTION0.7 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE0.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG SPORATIC13.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB56.5 ft. MGO - General Observation - MAG COAT 30%62.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB94.3 ft. MGO - General Observation - RUST ON CONCRETE 12:00103.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - STUB109.7 ft. MGO - General Observation - 10% OLD MAG COAT109.7 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC115.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC115.8 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE117.8 ft. AMH - Downstream Manhole, Survey Begins - 12:25AM117.8 ft. MWM - Water Mark, 10 %of cross sectional area117.8 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (6)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • General Observation - 10% OLD MAG COAT

    8.1 ft. - General Observation - 10% OLD MAG COAT

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    8.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • General Observation - RUST ON CONCRETE 12:00

    23.5 ft. - General Observation - RUST ON CONCRETE 12:00

  • General Observation - MAG COAT 30%

    61.3 ft. - General Observation - MAG COAT 30%

Observations (15)

DistanceCodeObservation
61.3MGOMAG COAT 30%
14.7TFCSTUB
2SAVSEVERE AGG SPORATIC
8.1MGO10% OLD MAG COAT
8.1SAVSEVERE AGG SPORATIC
0AMH12:25AM
117.1SSSBLISTERING PEELING CONCRETE
2SSSBLISTERING PEELING CONCRETE
104.4TFCSTUB
0MWM
23.5MGORUST ON CONCRETE 12:00
117.1SAVSEVERE AGG SPORATIC
0MWL
55.4TFCSTUB
117.8AMH12:45AM(COMPLETED BY REVERSE INSPECTION

Properties (7)

additional_info
REVERSE INSPECTION
custom_field_three
SEVERE AGG VISIBLE SPORATIC
custom_field_two
4
customer
LACSD
datetime
2019-12-18T00:21:28-08:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false