- Date
- 12/17/2019
- W/O
- 0807676
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00282
- PipeID
- P03664
- Time
- 2:42 AM
- Certificate
- 1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0301
- Sewer Name
- 02 MONTEBELLO DIVERSION TRUNK
- City
- MONTEBELLO
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 18
- Purpose
- Routine Assessment
- Project
- 20191216MDM_MONTEBELLO_DIVERSION_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 02 1090
- Downstream MH
- 02 1089
- Dir. of Survey
- Downstream
- Length Surveyed
- 228.7 ft.
- Total Length
- 228.7 ft.
- Structural Index
- 3
- Structural Quick
- 3H2H
- Structural Rating
- 230
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 230
Pipe schematic from manhole 02 1090 to 02 1089 Observation photos (5)

2 ft. - General Observation - 20% OLD MAG COAT START

2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG VERY SPORATIC

2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

27.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

208.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE