Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2019, 10:42 AM
  • 2_1_3_16122019_024539.mp4

Date
12/16/2019
W/O
0807676
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00282
PipeID
P03669
Time
2:42 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0300
Sewer Name
02 MONTEBELLO DIVERSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
20191216MDM_MONTEBELLO_DIVERSION_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 1993
Downstream MH
02 1094
Dir. of Survey
Downstream
Length Surveyed
379.8 ft.
Total Length
379.8 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
386
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
386
Pipe schematic from manhole 02 1993 to 02 1094
MH: 02 1993MH: 02 1094downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:00AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE OUTGOING0 ft. MWL - Water Level, 0 %of cross sectional area0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE INCOMING2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG4.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR9 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR9 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG14.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC14.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG19.2 ft. MGP - General Photograph - VERY SPORATIC SEVERE AGG75.4 ft. MGO - General Observation - OLD MAG COAT 20% START236 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC379.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG VERY SPORATIC379.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE379.8 ft. AMH - Downstream Manhole, Survey Ends - 3:45AAM

Observation photos (10)

  • General Observation - MH CONN 9:00 ACTIVE OUTGOING

    0 ft. - General Observation - MH CONN 9:00 ACTIVE OUTGOING

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    4.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    14.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • General Photograph - VERY SPORATIC SEVERE AGG

    19.2 ft. - General Photograph - VERY SPORATIC SEVERE AGG

  • General Observation - OLD MAG COAT 20% START

    75.4 ft. - General Observation - OLD MAG COAT 20% START

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC

    236 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC

Observations (20)

DistanceCodeObservation
9SRCCIRCUM REBAR
14.6SAVSEVERE AGG SPORATIC
379.8AMH3:45AAM
0AMH3:00AM
236SAVSEVERE AGG VERY SPORATIC
14.6SAVSEVERE AGG
19.2MGPVERY SPORATIC SEVERE AGG
0MWM
9SAMSEVERE AGG
4.5SRCCIRCUM REBAR
379.5SAVSEVERE AGG VERY SPORATIC
9SSSPEELING CONCRETE
0MGOMH CONN 9:00 ACTIVE OUTGOING
75.4MGOOLD MAG COAT 20% START
379.5SSSBLISTERING PEELING CONCRETE
0MWL
0MGOMH CONN 3:00 ACTIVE INCOMING
9SAVSEVERE AGG
2SSSBLISTERING PEELING CONCRETE
2SAMSEVERE AGG

Properties (6)

custom_field_three
CIRCUM REBAR CORRODED 1 AREA
custom_field_two
2
customer
LACSD
datetime
2019-12-16T02:42:51-08:00
documentation
MARTIN,REVELES,IGNACIO
is_lateral_inspection
false