- Date
- 12/13/2019
- W/O
- 0802971
- Weather
- Dry
- Operator/Surveyor
- BRAR
- Sewer ID
- Z00598
- PipeID
- P12260
- Time
- 9:10 AM
- Certificate
- U-0618-07030022
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I 0295
- Sewer Name
- 15 BALDWIN PARK TRUNK
- City
- LA PUENTE
- Loc. details
- Other
- Location Code
- Z
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- 20191213SB_BALDWIN_PARK_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Upstream MH
- 15 0333
- Downstream MH
- 15 0334
- Dir. of Survey
- Upstream
- Length Surveyed
- 2 ft.
- Total Length
- 2 ft.
- Structural Index
- 4
- Structural Quick
- 5231
- Structural Rating
- 15
- O&M Index
- 1
- O&M Quick
- 1100
- O&M Rating
- 1
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole 15 0333 to 15 0334 Observation photos (3)

1.9 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - CORRODED BEYOND REBAR

1.9 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

1.9 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES