- Date
- 12/14/2019
- W/O
- 0803064
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00471
- PipeID
- P06926
- Time
- 1:19 AM
- Certificate
- 1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0296
- Sewer Name
- 05 LOMITA TRUNK
- City
- TORRANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Capital Improvement Program Assesment
- Project
- 20191213MDM_LOMITA_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 05 1700
- Downstream MH
- 05 1699
- Dir. of Survey
- Downstream
- Length Surveyed
- 223.7 ft.
- Total Length
- 223.7 ft.
- Structural Index
- 2
- Structural Quick
- 412G
- Structural Rating
- 84
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 84
Pipe schematic from manhole 05 1700 to 05 1699 Observation photos (3)

62.2 ft. - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT & HAIRLINE FRACTURES AT JOINTS

132.6 ft. - General Photograph - 21" VCP

194.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT