Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 23, 2019, 09:20 AM
  • NA_29 0456 _23072019_024121.mp4

Date
07/23/2019
W/O
776901
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00537
PipeID
P24498
Time
2:20 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6719
Sewer Name
29 21ST STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_776901_TV29107_JUL2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0456
Downstream MH
NA
Dir. of Survey
Upstream
Length Surveyed
245.9 ft.
Total Length
245.9 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
144
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
144
Pipe schematic from manhole 29 0456 to NA
MH: 29 0456MH: NAupstream0 ft. MGO - General Observation - PIPE SEALED OFF0 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6"0 ft. AMH - Upstream Manhole, Survey Ends - END OF PIPE0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish45 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6"99.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"120.2 ft. TFB - Tap Factory Made Abandoned, at 09 o'clock, -, within 8 inches of joint: YES, 6", 6"150.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6"162.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"226.4 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"240.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start245.9 ft. AMH - Downstream Manhole, Survey Begins - 29 0456245.9 ft. MWL - Water Level, 5 %of cross sectional area245.9 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
245.9MGOPIPE SEALED OFF
245.9TF
245.9AMHEND OF PIPE
200.9TF
245.9CM
83TB
125.7TFB
0AMH29 0456
95.4TF
0MWL
19.5TFA
146.4TF
0MWM
5.7CM

Properties (6)

additional_info
SC378218
custom_field_two
3
customer
LACSD
datetime
2019-07-23T02:20:51-07:00
documentation
PROPIPE
is_lateral_inspection
false