Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 11, 2019, 09:13 AM
  • H 1261_H 1260_12112019_Manual1.mp4

Date
12/11/2019
W/O
0798055
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01181
PipeID
P17186
Time
1:13 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0289
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
IRWINDALE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
25
Purpose
Routine Assessment
Project
20191211MDM_JOINT_OUTFALL_H_UNIT_8K
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
H 1261
Downstream MH
H 1260
Dir. of Survey
Downstream
Length Surveyed
10.5 ft.
Total Length
10.5 ft.
Structural Index
3
Structural Quick
4221
Structural Rating
10
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole H 1261 to H 1260
MH: H 1261MH: H 1260downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:55AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG10.2 ft. MWL - Water Level, 80 %of cross sectional area10.2 ft. MWM - Water Mark, 100 %of cross sectional area10.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG10.2 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHTLY FLAKING CONCRETE10.5 ft. MSA - Survey Abandoned - DOWNLEG UPSTREAM SIPHON

Observations (9)

DistanceCodeObservation
10.2MWL
2SAMSEVERE AGG
10.2MWM
10.5MSADOWNLEG UPSTREAM SIPHON
10.2SAMSEVERE AGG
10.2SSSSLIGHTLY FLAKING CONCRETE
0MWM
0AMH2:55AM
0MWL

Properties (7)

additional_info
DOWNLEG UPSTREAM SIPHON
custom_field_three
MISSING SEVERE AGG
custom_field_two
3
customer
LACSD
datetime
2019-12-11T01:13:12-08:00
documentation
MARTIN ,OLIVER 111,IGNACIO
is_lateral_inspection
false