Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 10, 2019, 07:02 AM
  • 22 0564_22 0563 _09102019_002811.mp4

Date
09/10/2019
W/O
787674
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00791
PipeID
P16907
Time
12:02 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6817
Sewer Name
22 BEN LOMOND TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
21
Purpose
Routine Assessment
Project
WO_787674_TV22006_SEP2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0563
Downstream MH
22 0564
Dir. of Survey
Upstream
Length Surveyed
457.3 ft.
Total Length
457.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 22 0563 to 22 0564
MH: 22 0563MH: 22 0564upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 05642.1 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish61.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"67.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"107.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"132.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"183.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"259 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"299.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"344.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"350.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"406.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"410.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"455.3 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start457.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK457.3 ft. AMH - Downstream Manhole, Survey Begins - 22 0563457.3 ft. MWM - Water Mark, 20 %of cross sectional area457.3 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
2SAV
157.6TFC
455.2SAV
324.6TFC
279.5TFC
349.8TFC
457.3AMH22 0564
0MGOCONNECTION AT MH 3 O'CLOCK
112.5TFC
51TFC
107.2TFC
274TFC
389.7TFC
395.4TFC
0AMH22 0563
198.3TFC
0MWM
46.9TFC
0MWL

Properties (6)

additional_info
SC378429
custom_field_two
3
customer
LACSD
datetime
2019-09-10T00:02:27-07:00
documentation
PRO PIPE
is_lateral_inspection
false