Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 10, 2019, 05:11 AM
  • 22 0563_22 0562 _09092019_224847.mp4

Date
09/09/2019
W/O
787674
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00791
PipeID
P16906
Time
10:11 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6817
Sewer Name
22 BEN LOMOND TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
21
Purpose
Routine Assessment
Project
WO_787674_TV22006_SEP2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0563
Downstream MH
22 0562
Dir. of Survey
Downstream
Length Surveyed
404.8 ft.
Total Length
404.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 22 0563 to 22 0562
MH: 22 0563MH: 22 0562downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 05630 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start7.1 ft. MGO - General Observation - MAG COAT THROUGHOUT24.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"29.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"100.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"105.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"170.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"176.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"226.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"257.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"313 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"328.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"363.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"402.4 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish404.8 ft. AMH - Downstream Manhole, Survey Ends - 22 0562

Observation photos (2)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT THROUGHOUT

    7.1 ft. - General Observation - MAG COAT THROUGHOUT

Observations (19)

DistanceCodeObservation
0MWL
2SAV
24.3TFC
105.7TF
7.1MGOMAG COAT THROUGHOUT
313TFC
328.5TF
0AMH22 0563
404.8AMH22 0562
100.3TFC
402.4SAV
176.4TF
0MWM
363.7TF
29.7TFC
257.4TF
226.6TFC
170.9TFC
0MGOCONNECTION AT MH 9 O'CLOCK

Properties (6)

additional_info
SC378429
custom_field_two
3
customer
LACSD
datetime
2019-09-09T22:11:32-07:00
documentation
PRO PIPE
is_lateral_inspection
false