Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 20, 2019, 06:34 AM
  • 22 0547_22 0546 _09192019_235859.mp4

Date
09/19/2019
W/O
787674
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00791
PipeID
P16889
Time
11:34 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6082
Sewer Name
22 BEN LOMOND TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary
District
District 22
Page No.
20
Purpose
Routine Assessment
Project
WO_787674_TV22006_SEP2019
Sewer Type
ZZ
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0547
Downstream MH
22 0546
Dir. of Survey
Downstream
Length Surveyed
429.6 ft.
Total Length
429.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 22 0547 to 22 0546
MH: 22 0547MH: 22 0546downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 05470 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.6 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"30 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"107.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"141.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"204.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"206.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"217.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"319.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"368.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"396.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"423.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish429.6 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK429.6 ft. AMH - Downstream Manhole, Survey Ends - 22 0546

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

    26.6 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

Observations (20)

DistanceCodeObservation
319.3TF
294.9TF
141.1TB
107.6TB
0MWL
429.6MGOCONNECTION AT MH 6 O'CLOCK
0AMH22 0547
206.7TB
204.9TFC
429.6AMH22 0546
0MWM
368.6TF
2SAV
217.3TF
396.9TFC
30TFC
143.8TFC
423.8SAV
26.6TBI
0MGOCONNECTION AT MH 6 O'CLOCK

Properties (6)

additional_info
SC378429
custom_field_two
3
customer
LACSD
datetime
2019-09-19T23:34:06-07:00
documentation
PRO PIPE
is_lateral_inspection
false