Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2019, 12:09 PM
  • 1_1_2_18122019_041335.mp4

Date
12/18/2019
W/O
0793102
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00701
PipeID
P14791
Time
4:09 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0303R
Sewer Name
18 SCOTT AVENUE RELIEF TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Maintenance Related
Project
20191218MDM_SCOTT_AVENUE_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
18 0944
Downstream MH
18 0943
Dir. of Survey
Downstream
Length Surveyed
264.2 ft.
Total Length
264.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0944 to 18 0943
MH: 18 0944MH: 18 0943downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:15AM182.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN186.8 ft. MGO - General Observation - 7.5" VCP-PVCP264.2 ft. AMH - Downstream Manhole, Survey Ends - 4:35AM

Observation photos (1)

  • General Observation - 7.5" VCP-PVCP

    186.8 ft. - General Observation - 7.5" VCP-PVCP

Observations (6)

DistanceCodeObservation
186.8MGO7.5" VCP-PVCP
0MWL
0MWM
0AMH4:15AM
182.3TBOPEN
264.2AMH4:35AM

Properties (6)

additional_info
PRE ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-12-18T04:09:55-08:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false
lining
PVCP-Folded/Reformed