Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 11, 2019, 07:20 AM
  • 30 0329_30 0328 _12102019_232951.mp4

Date
12/10/2019
W/O
798601
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00878
PipeID
P18002
Time
11:20 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7207
Sewer Name
30 SOUTH BAY CITIES MAIN TRUNK
City
TORRANCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
05
Purpose
Routine Assessment
Project
WO_798601_TV30036_NOV2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
30 0329
Downstream MH
30 0328
Dir. of Survey
Downstream
Length Surveyed
300.2 ft.
Total Length
300.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 30 0329 to 30 0328
MH: 30 0329MH: 30 0328downstream0 ft. AMH - Upstream Manhole, Survey Begins - 30 03290 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area25.3 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"26.3 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"62.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"163.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES164.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"241.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"300.2 ft. AMH - Downstream Manhole, Survey Ends - 30 0328

Observation photos (2)

  • Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"

    25.3 ft. - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"

    26.3 ft. - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"

Observations (11)

DistanceCodeObservation
0AMH30 0329
300.2AMH30 0328
0MWM
241.6TF
91.9TFC
164.5TFA
25.3TBA
163.6DAGS
62.2TFC
0MWL
26.3TBA

Properties (6)

additional_info
SC365800
custom_field_two
4
customer
LACSD
datetime
2019-12-10T23:20:38-08:00
documentation
PROPIPE
is_lateral_inspection
false