Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2019, 06:20 AM
  • B 0569_B 0568A _12092019_223628.mp4

Date
12/09/2019
W/O
798600
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00101
PipeID
P09118
Time
10:20 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7146
Sewer Name
B JOINT OUTFALL B - UNIT 7
City
ROSEMEAD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
26
Purpose
Routine Assessment
Project
WO_798600_TV15120_NOV2019
Sewer Type
Gravity
Material
CIP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
B 0569
Downstream MH
B 0568A
Dir. of Survey
Downstream
Length Surveyed
347.6 ft.
Total Length
347.6 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
207
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
3
Overall Quick
Overall Rating
345
Pipe schematic from manhole B 0569 to B 0568A
MH: B 0569MH: B 0568Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - B 05690 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start345.8 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish345.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish347.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE347.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK347.6 ft. AMH - Downstream Manhole, Survey Ends - B 0568A

Observation photos (3)

  • Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    347.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
345.8SCP
2SCP
347.6MGOCOCKROACHES IN MANHOLE
345.8DAGS
0AMHB 0569
0MWL
347.6MGOCONNECTION AT MH 9 O'CLOCK
2DAGS
347.6AMHB 0568A
0MWM

Properties (6)

additional_info
SC378878
custom_field_two
2
customer
LACSD
datetime
2019-12-09T22:20:56-08:00
documentation
PRO PIPE
is_lateral_inspection
false