Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2019, 06:18 AM
  • 02 0110_02 0109 _12042019_223952.mp4

Date
12/04/2019
W/O
798354
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00237
PipeID
P02277
Time
10:18 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7141
Sewer Name
02 BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_798354_TV02350_NOV2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
02 0110
Downstream MH
02 0109
Dir. of Survey
Downstream
Length Surveyed
337.3 ft.
Total Length
337.3 ft.
Structural Index
3
Structural Quick
5243
Structural Rating
360
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
498
Pipe schematic from manhole 02 0110 to 02 0109
MH: 02 0110MH: 02 0109downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 01100 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES AT MH2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES26.2 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES73.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN87.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"96.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"123 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN147 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN173.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"185.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"200.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN227.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"242 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"268.7 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - CONN/OFF-SET/OPEN280.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"294.8 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - CONN BROKEN/OPEN332.3 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start332.3 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES, Start335 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish335.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish335.6 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish335.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish335.7 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish337.3 ft. AMH - Downstream Manhole, Survey Ends - 02 0109337.3 ft. MGO - General Observation - COCKROACHES AT MH337.3 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (7)

  • General Observation - COCKROACHES AT MH

    0 ft. - General Observation - COCKROACHES AT MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    7.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    26.2 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    332.3 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES AT MH

    337.3 ft. - General Observation - COCKROACHES AT MH

Observations (34)

DistanceCodeObservation
335SSS
280.4TFA
242TFC
268.7TFDCONN/OFF-SET/OPEN
0MWM
173.9TFA
335.6DAGS
96.2TFA
337.3AMH02 0109
200.7TFC
337.3MGOCOCKROACHES AT MH
2SSS
227.1TFC
0AMH02 0110
73.1TFOPEN
7.9FL
332.3FM
185.7TFC
335.6FM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
221.5TFOPEN
26.2FM
123TFUNKNOWN
294.8TFDCONN BROKEN/OPEN
0MGOCOCKROACHES AT MH
332.3B
87.8TFA
335.6CM
2DAGS
147TFUNKNOWN
337.3MGOCONN @ MH 3 O'CLOCK/ACTIVE
335.7B
2CM

Properties (6)

additional_info
SC378873
custom_field_two
2
customer
LACSD
datetime
2019-12-04T22:18:08-08:00
documentation
PRO PIPE
is_lateral_inspection
false