- Date
- 12/16/2019
- W/O
- 798664
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00190
- PipeID
- P11025
- Time
- 10:00 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7154
- Sewer Name
- H JOINT OUTFALL H - UNIT 8G
- City
- BALDWIN PARK
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 24
- Purpose
- Resurvey For Any Reason
- Project
- RFIR_WO_798664_TV15233_NOV2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Width
- 42 in.
- Upstream MH
- H 0604
- Downstream MH
- H 0603
- Dir. of Survey
- Downstream
- Length Surveyed
- 614.2 ft.
- Total Length
- 614.2 ft.
- Structural Index
- 3
- Structural Quick
- 5M3W
- Structural Rating
- 970
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 970
Pipe schematic from manhole H 0604 to H 0603 Observation photos (3)

2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start