18 0657_18 0656 _12112019_032317.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
5 ft. - Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES
20.4 ft. - Deposits Attached Other, 5 %of cross sectional area, from 06 to 12 o'clock, , within 8 inches of joint: YES
56.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
61.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
120.9 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
120.9 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
161.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start
170.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start
212 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
302.1 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 167.5 | CL | — |
| 327.3 | AMH | 18 0657 |
| 5 | FM | — |
| 120.9 | TBA | — |
| 319.6 | TFA | — |
| 20.4 | DAZ | — |
| 120.9 | TFC | — |
| 161.3 | CL | — |
| 56.9 | CL | — |
| 0 | MWM | — |
| 212 | CL | — |
| 120.9 | CL | — |
| 170.8 | CL | — |
| 61.5 | CL | — |
| 120.9 | CL | — |
| 180.7 | CL | — |
| 325.1 | DAGS | — |
| 302.1 | FM | — |
| 222.3 | TFC | — |
| 0 | MWL | — |
| 0 | AMH | 18 0656 |
| 216.6 | TFC | — |
| 115.6 | TFC | — |
| 314.8 | TFA | — |
| 2 | DAGS | — |