- Date
- 11/25/2019
- W/O
- 798062
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00821
- PipeID
- P17096
- Time
- 2:05 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7175
- Sewer Name
- 22 PUDDINGSTONE TRUNK, SECTS 1&2
- City
- SAN DIMAS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 22
- Purpose
- Routine Assessment
- Project
- WO_798062_TV22060_NOV2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 22 0739A
- Downstream MH
- 22 0739
- Dir. of Survey
- Downstream
- Length Surveyed
- 317.1 ft.
- Total Length
- 317.1 ft.
- Structural Index
- 3
- Structural Quick
- 3L2L
- Structural Rating
- 315
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 128
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 443
Pipe schematic from manhole 22 0739A to 22 0739 Observation photos (3)

2.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start