Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 22, 2019, 06:44 AM
  • 03 0412_03 0411 _11212019_230907.mp4

Date
11/21/2019
W/O
798173
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00373
PipeID
P05174
Time
10:44 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7173
Sewer Name
03 MARINA TRUNK, SECTION 4
City
LONG BEACH
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_798173_TV03163_NOV2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
03 0412
Downstream MH
03 0411
Dir. of Survey
Downstream
Length Surveyed
302.4 ft.
Total Length
302.4 ft.
Structural Index
4
Structural Quick
4J38
Structural Rating
240
O&M Index
2
O&M Quick
412K
O&M Rating
124
Overall Index
3
Overall Quick
Overall Rating
364
Pipe schematic from manhole 03 0412 to 03 0411
MH: 03 0412MH: 03 0411downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 04120 ft. MGO - General Observation - DEBRIS AT MH0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.3 ft. FS - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE28 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start57 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - FRACTURE MOVES FROM 12 TO 11 O'CLOCK72.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - fRACTURE MOVES FROM 12 TO 11 O'CLOCK96 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - fRACTURE MOVES FROM 12 TO 11 O'CLOC135.1 ft. MWL - Water Level, 40 %of cross sectional area150.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"300.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish300.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish302.4 ft. AMH - Downstream Manhole, Survey Ends - 03 0411302.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

    2.3 ft. - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    28 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
0AMH03 0412
2.3DAGS
28FM
300.2FM
0MGODEBRIS AT MH
0MWM
72.1FLfRACTURE MOVES FROM 12 TO 11 O'CLOCK
135.1MWL
150.7TFC
47.1FL
0MWL
300.2DAGS
57FLFRACTURE MOVES FROM 12 TO 11 O'CLOCK
302.4AMH03 0411
302.4MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0MGOCONNECTION AT MH 9 O'CLOCK CAPPED
2.3FSAT MOUTH OF PIPE
96FLfRACTURE MOVES FROM 12 TO 11 O'CLOC

Properties (6)

additional_info
SC398413
custom_field_two
1
customer
LACSD
datetime
2019-11-21T22:44:27-08:00
documentation
PROPIPE
is_lateral_inspection
false