- Date
- 11/15/2019
- W/O
- 792653
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00028
- PipeID
- P11271
- Time
- 3:41 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7162
- Sewer Name
- E JOINT OUTFALL E - UNIT 2
- City
- COMPTON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- RFIR_WO_792653_TV01124_OCT2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 48 in.
- Width
- 48 in.
- Upstream MH
- E 0044
- Downstream MH
- E 0043
- Dir. of Survey
- Downstream
- Length Surveyed
- 81.6 ft.
- Total Length
- 81.8 ft.
- Structural Index
- 3
- Structural Quick
- 3B2B
- Structural Rating
- 80
- O&M Index
- 2
- O&M Quick
- 312B
- O&M Rating
- 35
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 115
Pipe schematic from manhole E 0044 to E 0043 Observation photos (5)

3.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.9 ft. - Deposits Settled Compacted, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

3.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

81.4 ft. - Obstacles Rocks, 15 %of cross sectional area, from 04 to 07 o'clock

81.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish