Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 12, 2019, 12:05 PM
  • 29 0445_29 0735 _11122019_041721.mp4

Date
11/12/2019
W/O
792790
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01090
PipeID
P24485
Time
4:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6331
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_792790_TV29104_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0445
Downstream MH
29 0735
Dir. of Survey
Downstream
Length Surveyed
247.6 ft.
Total Length
247.6 ft.
Structural Index
4
Structural Quick
4I3I
Structural Rating
343
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
343
Pipe schematic from manhole 29 0445 to 29 0735
MH: 29 0445MH: 29 0735downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 04450 ft. MWL - Water Level, 5 %of cross sectional area3.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"50 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"55.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"100.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"160.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"212 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"214.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"244.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"247.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish247.6 ft. AMH - Downstream Manhole, Survey Ends - 29 0735247.6 ft. MGO - General Observation - CONNECTION AT 9 O'CLOCK

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
100.9TF
55.7TF
214.1TFC
212TF
160.3TF
154.8TF
0MWM
244.3TF
247.6AMH29 0735
0AMH29 0445
106.4TF
247.4FM
3.5FM
50TF
247.6MGOCONNECTION AT 9 O'CLOCK
0MWL
7.8TF

Properties (6)

additional_info
SC365774
custom_field_two
2
customer
LACSD
datetime
2019-11-12T04:05:30-08:00
documentation
PROPIPE
is_lateral_inspection
false