Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2019, 09:54 AM
  • H 1204_H 1203 _11142019_022054.mp4

Date
11/14/2019
W/O
792811
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01182
PipeID
P17630
Time
1:54 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6338
Sewer Name
H JOINT OUTFALL H - UNIT 8K RELIEF
City
AZUSA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Routine Assessment
Project
WO_792811_TV15041_OCT2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
H 1204
Downstream MH
H 1203
Dir. of Survey
Downstream
Length Surveyed
647.6 ft.
Total Length
647.6 ft.
Structural Index
2
Structural Quick
322X
Structural Rating
258
O&M Index
2
O&M Quick
2X11
O&M Rating
253
Overall Index
2
Overall Quick
Overall Rating
511
Pipe schematic from manhole H 1204 to H 1203
MH: H 1204MH: H 1203downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 12040.1 ft. MWM - Water Mark, 35 %of cross sectional area2.2 ft. MGO - General Observation - MAG COAT2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start433.1 ft. VC - Vermin Cockroach, within 8 inches of joint: YES647 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish647 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish647.6 ft. AMH - Downstream Manhole, Survey Ends - H 1203647.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Upstream Manhole, Survey Begins - H 1204

    0 ft. - Upstream Manhole, Survey Begins - H 1204

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    15.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    16.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Vermin Cockroach, within 8 inches of joint: YES

    433.1 ft. - Vermin Cockroach, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
2.2MGOMAG COAT
15.1SSS
647.6AMHH 1203
647.6SAP
647SSS
2.2SAP
433.1VC
0MWL
0AMHH 1204
16.1DAGS
647DAGS
0.1MWM

Properties (7)

additional_info
SC365781
custom_field_two
3
customer
LACSD
datetime
2019-11-14T01:54:28-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
30658