- Date
- 11/22/2019
- W/O
- 798188
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00362
- PipeID
- P04750
- Time
- 2:25 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7174
- Sewer Name
- C JOINT OUTFALL C - UNIT 4D
- City
- LONG BEACH
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- RFIR_WO_798188_TV03084_NOV2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- C 0566
- Downstream MH
- C 0565
- Dir. of Survey
- Downstream
- Length Surveyed
- 423.8 ft.
- Total Length
- 423.8 ft.
- Structural Index
- 2
- Structural Quick
- 3U2`
- Structural Rating
- 650
- O&M Index
- 2
- O&M Quick
- 412N
- O&M Rating
- 158
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 808
Pipe schematic from manhole C 0566 to C 0565 Observation photos (4)

6.9 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

31 ft. - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

51.4 ft. - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

240.4 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES