Search
Uploads
Inspections
Wastewater/Activity/PacpInspection/1.0
Nov 21, 2019, 10:36 AM
18 0960_18 0959_11212019_024337.mp4
Date
11/21/2019
W/O
0798462
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14808
Time
2:36 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
—
Pre-Cleaning
Not Known
Media Label
H1316
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
10
Purpose
Routine Assessment
Project
20191121MDM_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
9.399999618530273 in.
Upstream MH
18 0960
Downstream MH
18 0959
Dir. of Survey
Downstream
Length Surveyed
350.8 ft.
Total Length
350.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
2
Overall Quick
—
Overall Rating
4
Pipe schematic from manhole 18 0960 to 18 0959
MH: 18 0960
MH: 18 0959
downstream
0 ft. MWL - Water Level, 20 %of cross sectional area
0 ft. AMH - Upstream Manhole, Survey Begins - 2:45AM
0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active
0 ft. MWM - Water Mark, 40 %of cross sectional area
6.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open
275.8 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - Open-99% ROOTS
275.8 ft. RFC - Roots Fine Connection, from 02 to 03 o'clock, within 8 inches of joint: NO - 4%
281.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open
350.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active
350.8 ft. AMH - Downstream Manhole, Survey Ends - 3:05AM
All inspections of P14808
Work order 0798462
Observations (10)
Distance
Code
Observation
0
MWL
—
275.8
TBD
Open-99% ROOTS
0
AMH
2:45AM
350.4
MGO
Conn. @ Mh, 3 O' Clock. Active
281.2
TB
Open
6.8
TB
Open
0
MGO
Conn. @ Mh, 3 O' Clock. Active
0
MWM
—
275.8
RFC
4%
350.8
AMH
3:05AM
Properties (7)
custom_field_three
LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2019-11-21T02:36:06-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
PVCP