Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2019, 09:42 AM
  • 18 0962_18 0961_11212019_015235.mp4

Date
11/21/2019
W/O
0798462
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14811
Time
1:42 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1316
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
10
Purpose
Routine Assessment
Project
20191121MDM_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
9.399999618530273 in.
Upstream MH
18 0962
Downstream MH
18 0961
Dir. of Survey
Downstream
Length Surveyed
190.7 ft.
Total Length
190.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0962 to 18 0961
MH: 18 0962MH: 18 0961downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:50AM81.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open82.3 ft. MGO - General Observation - 9.4" VCP-PVCP88.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open190.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active190.7 ft. AMH - Downstream Manhole, Survey Ends - 2:00AM

Observation photos (1)

  • General Observation - 9.4" VCP-PVCP

    82.3 ft. - General Observation - 9.4" VCP-PVCP

Observations (9)

DistanceCodeObservation
82.3MGO9.4" VCP-PVCP
190.7AMH2:00AM
0MWM
88.7TBOpen
190.3MGOConn. @ Mh, 3 O' Clock. Active
0MGOConn. @ Mh, 3 O' Clock. Active
0MWL
81.7TBOpen
0AMH1:50AM

Properties (7)

custom_field_three
LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2019-11-21T01:42:10-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
PVCP