Section#3_22 0626_22 0625__1232019__I0276.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
9.4 ft. - Surface Missing Wall, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SOIL VISIBLE VOID START
9.4 ft. - Surface Missing Wall, from 09 to 03 o'clock, within 8 inches of joint: YES - VOID SOIL SAND & ROCK VISIBLE
11.3 ft. - Surface Missing Wall, from 08 to 11 o'clock, within 8 inches of joint: YES - DEEP VOID
12.5 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG & CONCRETE
14.7 ft. - Surface Missing Wall, from 02 to 03 o'clock, within 8 inches of joint: YES - VOID SOIL VISIBLE
17.3 ft. - Surface Missing Wall, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - VOID SOIL VISIBLE
17.3 ft. - Surface Missing Wall, from 09 to 10 o'clock, within 8 inches of joint: YES - SOIL VISIBLE
20.5 ft. - Surface Missing Wall, from 01 to 04 o'clock, within 8 inches of joint: YES - SOIL VISIBLE
21.7 ft. - Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: NO, - SOIL VISIBLE APPOX 2.5' LONG
21.8 ft. - Surface Missing Wall, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - VOID SOIL VISIBLE
26 ft. - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
28.5 ft. - Surface Missing Wall, from 12 to 02 o'clock, within 8 inches of joint: NO - VOID SOIL VISIBLE
37.7 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
63.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - DEEP PEELING CONCRETE
87.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED
150.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED
| Distance | Code | Observation |
|---|---|---|
| 323.4 | SAM | SEVERE AGG |
| 14.7 | SMW | VOID SOIL VISIBLE |
| 12.5 | SAM | SEVERE AGG & CONCRETE |
| 121.7 | TFC | STUB |
| 9.4 | SMW | SOIL VISIBLE VOID START |
| 0 | MGO | MH CONN 9:00 ACTIVE |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 150.4 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 279.1 | TF | OPEN |
| 217.6 | TF | ACTIVE |
| 17.3 | SMW | VOID SOIL VISIBLE |
| 21.8 | SMW | VOID SOIL VISIBLE |
| 72 | TF | OPEN |
| 25 | SMW | VOID SOIL VISIBLE |
| 0 | MWM | — |
| 37.6 | SAM | SEVERE AGG & CONCRETE |
| 17.3 | SMW | SOIL VISIBLE |
| 0 | AMH | 2:30PM |
| 323.4 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 63.7 | SSS | DEEP PEELING CONCRETE |
| 323.4 | SSS | BLISTERING PEELING CONCRETE |
| 0 | MWL | — |
| 7.9 | SAM | SEVERE AGG |
| 2 | SAM | SEVERE AGG |
| 87.8 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 21.7 | SMW | SOIL VISIBLE APPOX 2.5' LONG |
| 20.5 | SMW | SOIL VISIBLE |
| 11.3 | SMW | DEEP VOID |
| 37.7 | SAM | SEVERE AGG |
| 12.5 | SMW | VOID SOIL VISIBLE |
| 20.3 | SMW | VOID SOIL VISIBLE |
| 26 | SMW | SOIL VISIBLE |
| 323.8 | AMH | 3:40AM |
| 28.5 | SMW | VOID SOIL VISIBLE |
| 9.4 | SMW | VOID SOIL SAND & ROCK VISIBLE |