- Date
- 12/03/2019
- W/O
- 0806003
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00827
- PipeID
- P16975
- Time
- 1:25 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0276
- Sewer Name
- 22 SUNFLOWER TRUNK
- City
- COVINA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 21
- Purpose
- Capital Improvement Program Assesment
- Project
- 20191203MDM_SUNFLOWER_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 22 0627
- Downstream MH
- 22 0626
- Dir. of Survey
- Downstream
- Length Surveyed
- 65.7 ft.
- Total Length
- 65.7 ft.
- Structural Index
- 3
- Structural Quick
- 4B31
- Structural Rating
- 87
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 87
Pipe schematic from manhole 22 0627 to 22 0626 Observation photos (5)

2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING PEELING CONCRETE

6.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

22.9 ft. - General Observation - 15" NRCP

36 ft. - Surface Aggregate Missing, from 08 to 12 o'clock, within 8 inches of joint: NO - SEVERE AGG