Section#1_22 0628_22 0627__1232019__I0276.mp4
0.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE
0.7 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
10.3 ft. - General Observation - 10% MAG COAT TOP OF PIPE SPORATIC
17.5 ft. - Surface Aggregate Missing, from 12 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG
24.8 ft. - General Observation - 15" NRCP
64 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
71.8 ft. - Surface Aggregate Projecting, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG
148.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE
303.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SWOLLEN PEELING CONCRETE
| Distance | Code | Observation |
|---|---|---|
| 341.6 | TF | OPEN |
| 24.8 | MGO | 15" NRCP |
| 286 | TB | OPEN |
| 368.8 | SSS | SWOLLEN BLISTERING PEELING CONCRETE |
| 0 | AMH | 12:35AM |
| 221.2 | TF | OPEN |
| 358.2 | TF | OPEN |
| 10.3 | MGO | 10% MAG COAT TOP OF PIPE SPORATIC |
| 0.7 | SSS | BLSTERING PEELING CONCRETE |
| 250.6 | TFC | STUB |
| 317.1 | TFC | STUB |
| 204.8 | TF | OPEN |
| 71.8 | SAP | SEVERE AGG |
| 97 | TF | OPEN |
| 148.9 | SSS | BLISTERING PEELING CONCRETE |
| 64 | SAM | SEVERE AGG |
| 17.5 | SAM | SEVERE AGG |
| 10.3 | TF | OPEN |
| 292.3 | TFC | STUB |
| 368.2 | SAM | SEVERE AGG |
| 368.8 | AMH | 1:15AM |
| 143 | TF | OPEN |
| 167.9 | TF | OPEN |
| 303.7 | SSS | SWOLLEN PEELING CONCRETE |
| 271.1 | TF | OPEN |
| 0.7 | SAM | SEVERE AGG |
| 48 | TF | OPEN |
| 35.2 | TFC | STUB |
| 0 | MWM | — |
| 0 | MWL | — |