Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 3, 2019, 08:29 AM
  • Section#1_22 0628_22 0627__1232019__I0276.mp4

Date
12/03/2019
W/O
0806003
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00827
PipeID
P16976
Time
12:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0276
Sewer Name
22 SUNFLOWER TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
21
Purpose
Capital Improvement Program Assesment
Project
20191203MDM_SUNFLOWER_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0628
Downstream MH
22 0627
Dir. of Survey
Downstream
Length Surveyed
368.8 ft.
Total Length
368.8 ft.
Structural Index
3
Structural Quick
4N31
Structural Rating
455
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
455
Pipe schematic from manhole 22 0628 to 22 0627
MH: 22 0628MH: 22 0627downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:35AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE0.7 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG10.3 ft. MGO - General Observation - 10% MAG COAT TOP OF PIPE SPORATIC10.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN17.5 ft. SAM - Surface Aggregate Missing, from 12 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG24.8 ft. MGO - General Observation - 15" NRCP35.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - STUB48 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN64 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG71.8 ft. SAP - Surface Aggregate Projecting, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG97 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN143 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN148.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE167.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN204.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN221.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN250.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB271.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN286 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN292.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB303.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SWOLLEN PEELING CONCRETE317.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - STUB341.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN358.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN368.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG368.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SWOLLEN BLISTERING PEELING CONCRETE368.8 ft. AMH - Downstream Manhole, Survey Ends - 1:15AM

Observation photos (9)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE

    0.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    0.7 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - 10% MAG COAT TOP OF PIPE SPORATIC

    10.3 ft. - General Observation - 10% MAG COAT TOP OF PIPE SPORATIC

  • Surface Aggregate Missing, from 12 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    17.5 ft. - Surface Aggregate Missing, from 12 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • General Observation - 15" NRCP

    24.8 ft. - General Observation - 15" NRCP

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    64 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Projecting, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG

    71.8 ft. - Surface Aggregate Projecting, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE

    148.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SWOLLEN PEELING CONCRETE

    303.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SWOLLEN PEELING CONCRETE

Observations (30)

DistanceCodeObservation
341.6TFOPEN
24.8MGO15" NRCP
286TBOPEN
368.8SSSSWOLLEN BLISTERING PEELING CONCRETE
0AMH12:35AM
221.2TFOPEN
358.2TFOPEN
10.3MGO10% MAG COAT TOP OF PIPE SPORATIC
0.7SSSBLSTERING PEELING CONCRETE
250.6TFCSTUB
317.1TFCSTUB
204.8TFOPEN
71.8SAPSEVERE AGG
97TFOPEN
148.9SSSBLISTERING PEELING CONCRETE
64SAMSEVERE AGG
17.5SAMSEVERE AGG
10.3TFOPEN
292.3TFCSTUB
368.2SAMSEVERE AGG
368.8AMH1:15AM
143TFOPEN
167.9TFOPEN
303.7SSSSWOLLEN PEELING CONCRETE
271.1TFOPEN
0.7SAMSEVERE AGG
48TFOPEN
35.2TFCSTUB
0MWM
0MWL

Properties (6)

custom_field_three
SEVERE AGG MISSING
custom_field_two
2
customer
LACSD
datetime
2019-12-03T00:29:29-08:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false