Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 22, 2019, 11:20 AM
  • B 0473A_B 0473_11222019_032207.mp4

Date
11/22/2019
W/O
0798588
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00094
PipeID
P08998
Time
3:20 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1304R
Sewer Name
B JOINT OUTFALL B - UNIT 5D
City
SIERRA MADRE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
06
Purpose
Maintenance Related
Project
20191122MDM_JOINT_OUTFALL_B_UNIT_5D
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
B 0473
Downstream MH
B 0473A
Dir. of Survey
Upstream
Length Surveyed
80.1 ft.
Total Length
80.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4131
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole B 0473 to B 0473A
MH: B 0473MH: B 0473Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 3:40AM50.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open50.8 ft. RMC - Roots Medium Connection, from 12 to 03 o'clock, 10 %, within 8 inches of joint: YES77.1 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR - 2%80.1 ft. AMH - Downstream Manhole, Survey Begins - 3:30AM80.1 ft. MWL - Water Level, 10 %of cross sectional area80.1 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. STUB80.1 ft. MWM - Water Mark, 50 %of cross sectional area

Observation photos (1)

  • Roots Medium Connection, from 12 to 03 o'clock, 10 %, within 8 inches of joint: YES

    29.3 ft. - Roots Medium Connection, from 12 to 03 o'clock, 10 %, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0AMH3:30AM
3RFJ2%
0MWL
0MGOConn. @ Mh, 3 O' Clock. STUB
80.1AMH3:40AM
29.3TFOpen
0MWM
29.3RMC

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-11-22T03:20:07-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false