Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2019, 06:52 PM
  • 16 0371_16 0370 _11142019_110628.mp4

Date
11/14/2019
W/O
793293
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00665
PipeID
P13422
Time
10:52 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6820
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
WO_793293_TV16031_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
14 in.
Width
14 in.
Upstream MH
16 0371
Downstream MH
16 0370
Dir. of Survey
Downstream
Length Surveyed
278.1 ft.
Total Length
278.1 ft.
Structural Index
3
Structural Quick
3700
Structural Rating
21
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 16 0371 to 16 0370
MH: 16 0371MH: 16 0370downstream0 ft. AMH - Upstream Manhole, Survey Begins - 16 03710.1 ft. MWLS - Water Level, Sag in pipe, 35 %of cross sectional area0.1 ft. MWM - Water Mark, 30 %of cross sectional area0.2 ft. MGO - General Observation - CURED IN PLACE LINER3.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8" - OPEN23.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN191.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 8" - OPEN204.6 ft. LFW - Lining Failure Wrinkled, at 02 o'clock, within 8 inches of joint: NO, Start233.8 ft. LFW - Lining Failure Wrinkled, at 02 o'clock, within 8 inches of joint: NO, Finish278.1 ft. AMH - Downstream Manhole, Survey Ends - 16 0370

Observation photos (2)

  • General Observation - CURED IN PLACE LINER

    0.2 ft. - General Observation - CURED IN PLACE LINER

  • Lining Failure Wrinkled, at 02 o'clock, within 8 inches of joint: NO, Start

    204.6 ft. - Lining Failure Wrinkled, at 02 o'clock, within 8 inches of joint: NO, Start

Observations (10)

DistanceCodeObservation
0.1MWLS
233.8LFW
0.1MWM
3.3TFOPEN
0.2MGOCURED IN PLACE LINER
0AMH16 0371
23.7TFOPEN
204.6LFW
191.5TFOPEN
278.1AMH16 0370

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2019-11-14T10:52:43-08:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP