Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2019, 05:39 AM
  • 16 0355_16 0354 _10292019_215132.mp4

Date
10/29/2019
W/O
793293
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00665
PipeID
P13406
Time
10:39 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7094
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
WO_793293_TV16031_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0355
Downstream MH
16 0354
Dir. of Survey
Downstream
Length Surveyed
284.3 ft.
Total Length
284.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
312J
O&M Rating
115
Overall Index
2
Overall Quick
Overall Rating
115
Pipe schematic from manhole 16 0355 to 16 0354
MH: 16 0355MH: 16 0354downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 03552 ft. MLC - Lining Change, Cured in place2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start61.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"64.2 ft. TBD - Tap Break-In Defective, at 09 o'clock, -, , within 8 inches of joint: YES, 4", 6" - 25% GREASE-LATERAL/ACTIVE163.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"166.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"258.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN261.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"282.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish284.3 ft. AMH - Downstream Manhole, Survey Ends - 16 0354284.3 ft. MGO - General Observation - DAMAGED TROUGH

Observation photos (3)

  • Lining Change, Cured in place

    2 ft. - Lining Change, Cured in place

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - DAMAGED TROUGH

    284.3 ft. - General Observation - DAMAGED TROUGH

Observations (14)

DistanceCodeObservation
284.3AMH16 0354
0MWM
0MWL
258.7TFOPEN
0AMH16 0355
2MLC
64.2TBD25% GREASE-LATERAL/ACTIVE
166.7TFA
284.3MGODAMAGED TROUGH
282.6DAGS
2DAGS
261.6TFA
163.8TFA
61.8TFA

Properties (7)

additional_info
SC378731
custom_field_two
4
customer
LACSD
datetime
2019-10-29T22:39:26-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP