Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2019, 09:59 AM
  • 16 0302_16 0301 _11132019_020732.mp4

Date
11/13/2019
W/O
793293
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00665
PipeID
P13353
Time
1:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6334
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
21
Purpose
Routine Assessment
Project
WO_793293_TV16031_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
22 in.
Width
22 in.
Upstream MH
16 0302
Downstream MH
16 0301
Dir. of Survey
Downstream
Length Surveyed
194 ft.
Total Length
194 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
312G
O&M Rating
82
Overall Index
2
Overall Quick
Overall Rating
82
Pipe schematic from manhole 16 0302 to 16 0301
MH: 16 0302MH: 16 0301downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 03020 ft. MWL - Water Level, 20 %of cross sectional area0 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - @ MH2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.2 ft. MLC - Lining Change, Cured in place69.9 ft. RML - Roots Medium Lateral, at 12 o'clock, 35 %, within 8 inches of joint: NO69.9 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - 90% GREASE/ROOTS-LATERAL/ACTIVE191 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish193.5 ft. MGO - General Observation - CONN @ 3 O'CLOCK/ACTIVE194 ft. AMH - Downstream Manhole, Survey Ends - 16 0301

Observations (11)

DistanceCodeObservation
3.2MLC
193.5MGOCONN @ 3 O'CLOCK/ACTIVE
2DAGS
0MWM
69.9RML
191DAGS
0AMH16 0302
69.9TFD90% GREASE/ROOTS-LATERAL/ACTIVE
194AMH16 0301
0MWL
0VC@ MH

Properties (7)

additional_info
SC365777
custom_field_two
4
customer
LACSD
datetime
2019-11-13T01:59:00-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP