Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2019, 06:21 AM
  • 16 0295_16 0119 _11132019_222354.mp4

Date
11/13/2019
W/O
793293
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00665
PipeID
P13345
Time
10:21 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6336
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
ALHAMBRA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
23
Purpose
Routine Assessment
Project
WO_793293_TV16031_OCT2019
Sewer Type
Gravity
Material
BRICK-CTL
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
16 0295
Downstream MH
16 0119
Dir. of Survey
Downstream
Length Surveyed
335.1 ft.
Total Length
335.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3D12
O&M Rating
83
Overall Index
3
Overall Quick
Overall Rating
83
Pipe schematic from manhole 16 0295 to 16 0119
MH: 16 0295MH: 16 0119downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 02950 ft. VC - Vermin Cockroach, within 8 inches of joint: YES - @ MH0 ft. MGO - General Observation - CONN @ 9 O'CLOCK/OPEN3.7 ft. MLC - Lining Change, Cured in place202.2 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start335 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - @ MH335.1 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish335.1 ft. MGO - General Observation - CONN @ 11 O'CLOCK/OPEN335.1 ft. AMH - Downstream Manhole, Survey Ends - 16 0119

Observations (11)

DistanceCodeObservation
202.2DSZ
3.7MLC
0MWL
0MWM
335.1DSZ
0AMH16 0295
335.1MGOCONN @ 11 O'CLOCK/OPEN
0VC@ MH
0MGOCONN @ 9 O'CLOCK/OPEN
335.1AMH16 0119
335VC@ MH

Properties (7)

additional_info
SC365779
custom_field_two
4
customer
LACSD
datetime
2019-11-13T22:21:53-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP