Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 6, 2019, 06:07 AM
  • F 0055_F 0054_11052019_223601.mp4

Date
11/05/2019
W/O
792836
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00035
PipeID
P10140
Time
10:07 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7086
Sewer Name
F JOINT OUTFALL F - UNIT 3A
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
WO_792836_TV02235_OCT2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Width
60 in.
Upstream MH
F 0055
Downstream MH
F 0054
Dir. of Survey
Downstream
Length Surveyed
298.7 ft.
Total Length
298.7 ft.
Structural Index
3
Structural Quick
3K2K
Structural Rating
290
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
295
Pipe schematic from manhole F 0055 to F 0054
MH: F 0055MH: F 0054downstream0 ft. MWL - Water Level, 65 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - F 00550.1 ft. MWM - Water Mark, 80 %of cross sectional area10 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start10.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start10.1 ft. MGO - General Observation - MAG COAT THROUGHOUT298.7 ft. MGO - General Observation - CABLE CAUGHT ON DEBRIS298.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish298.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish298.7 ft. AMH - Downstream Manhole, Survey Ends - F 0054

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    10.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWL
298.7MGOCABLE CAUGHT ON DEBRIS
10.1SSS
298.7SSS
0.1MWM
298.7SAP
10SAP
0AMHF 0055
10.1MGOMAG COAT THROUGHOUT
298.7AMHF 0054

Properties (6)

additional_info
SC378686
custom_field_two
3
customer
LACSD
datetime
2019-11-05T22:07:46-08:00
documentation
PROPIPE
is_lateral_inspection
false