Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 26, 2019, 05:46 AM
  • H 0295_H 0294 _11252019_221337.mp4

Date
11/25/2019
W/O
792818
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00174
PipeID
P10750
Time
9:46 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7177
Sewer Name
H JOINT OUTFALL H - UNIT 3
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_792818_TV02323_OCT2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
H 0295
Downstream MH
H 0294
Dir. of Survey
Downstream
Length Surveyed
3.9 ft.
Total Length
3.9 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole H 0295 to H 0294
MH: H 0295MH: H 0294downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 02950 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area1.9 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE3.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO3.7 ft. MGO - General Observation - TRACTOR SINKING INTO RESIDUE3.7 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - MAG COATING RESIDUE3.9 ft. MSA - Survey Abandoned - UNABLE TO CONTINUE

Observation photos (4)

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

    1.9 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO

    3.7 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO

  • Deposits Settled Other,  15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - MAG COATING RESIDUE

    3.7 ft. - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - MAG COATING RESIDUE

  • Survey Abandoned - UNABLE TO CONTINUE

    3.9 ft. - Survey Abandoned - UNABLE TO CONTINUE

Observations (8)

DistanceCodeObservation
0AMHH 0295
3.7SAP
0MWL
3.7MGOTRACTOR SINKING INTO RESIDUE
0MWM
3.7DSZMAG COATING RESIDUE
1.9SRVAT MOUTH OF PIPE
3.9MSAUNABLE TO CONTINUE

Properties (6)

additional_info
SC398417
custom_field_two
5
customer
LACSD
datetime
2019-11-25T21:46:24-08:00
documentation
PROPIPE
is_lateral_inspection
false