- Date
- 11/25/2019
- W/O
- 792818
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00174
- PipeID
- P10750
- Time
- 9:46 PM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7177
- Sewer Name
- H JOINT OUTFALL H - UNIT 3
- City
- PICO RIVERA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_792818_TV02323_OCT2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 57 in.
- Upstream MH
- H 0295
- Downstream MH
- H 0294
- Dir. of Survey
- Downstream
- Length Surveyed
- 3.9 ft.
- Total Length
- 3.9 ft.
- Structural Index
- 4
- Structural Quick
- 5131
- Structural Rating
- 8
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole H 0295 to H 0294 Observation photos (4)

1.9 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

3.7 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO

3.7 ft. - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - MAG COATING RESIDUE

3.9 ft. - Survey Abandoned - UNABLE TO CONTINUE