Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 21, 2019, 09:23 AM
  • 01 0565_01 0564A_02212019_014821.mp4

Date
02/21/2019
W/O
750737
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00194
PipeID
P25576
Time
1:23 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6280
Sewer Name
01 ALAMEDA STREET EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_750737_TV01001_FEB2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
01 0565
Downstream MH
01 0564A
Dir. of Survey
Downstream
Length Surveyed
369.3 ft.
Total Length
369.3 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0565 to 01 0564A
MH: 01 0565MH: 01 0564Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 05650 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. MGO - General Observation - 75% MAG COAT THROUGHOUT2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start365.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish369.3 ft. AMH - Downstream Manhole, Survey Ends - 01 0564A369.3 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
2MGO75% MAG COAT THROUGHOUT
0AMH01 0565
365.2SAP
369.3AMH01 0564A
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
0MWM
369.3MGOCONN @ MH 9 O'CLOCK/UNKNOWN
2SAP

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-02-21T01:23:52-08:00
documentation
PROPIPE
is_lateral_inspection
false