Wastewater/Activity/PacpInspection/1.0Oct 29, 2019, 08:47 AM
16 0339_16 0338 _10292019_010040.mp4
Date
10/29/2019
W/O
792820
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00665
PipeID
P13390
Time
1:47 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
—
Pre-Cleaning
No Pre-Cleaning
Media Label
K7096
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_792820_TV16061_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0338
Downstream MH
16 0339
Dir. of Survey
Upstream
Length Surveyed
300.6 ft.
Total Length
300.6 ft.
Structural Index
4
Structural Quick
4K3K
Structural Rating
413
O&M Index
2
O&M Quick
2W00
O&M Rating
238
Overall Index
3
Overall Quick
—
Overall Rating
651
Pipe schematic from manhole 16 0338 to 16 0339
Observation photos (4)
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
2.1 ft. - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - POSSIBLE MINERAL OR PIPE DISCOLORATION
3.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
30.5 ft. - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: YES, 4", 1"