- Date
- 11/14/2019
- W/O
- 792820
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00665
- PipeID
- P13386
- Time
- 2:07 PM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6822
- Sewer Name
- 16 SAN MARINO OUTFALL TRUNK
- City
- SAN MARINO
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- RFIR_WO_792820_TV16061_OCT2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Width
- 16 in.
- Upstream MH
- 16 0335
- Downstream MH
- 16 0334
- Dir. of Survey
- Downstream
- Length Surveyed
- 216 ft.
- Total Length
- 216 ft.
- Structural Index
- 4
- Structural Quick
- 4231
- Structural Rating
- 11
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 16 0335 to 16 0334 Observation photos (5)

0 ft. - General Observation - CONNECTIONS AT BOTH 3 AND 9 O'CLOCK IN MH

2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

60.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

85.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

129.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start