Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 11, 2019, 10:00 AM
  • 02 1795_02 1794_10112019_022223.mp4

Date
10/11/2019
W/O
792822
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00292
PipeID
P04140
Time
3:00 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7060
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
EAST LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_792822_TV02215_OCT2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1795
Downstream MH
02 1794
Dir. of Survey
Downstream
Length Surveyed
336 ft.
Total Length
336 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 02 1795 to 02 1794
MH: 02 1795MH: 02 1794downstream0 ft. MGO - General Observation - LINED PIPE0 ft. AMH - Upstream Manhole, Survey Begins - 02 17950 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area75.5 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN78.7 ft. TFC - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, OPEN118.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, OPEN122 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"126.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, OPEN162.7 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, OPEN186.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, OPEN187.3 ft. LFB - Lining Failure Blistered, from 06 to 08 o'clock, within 8 inches of joint: NO207.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE234.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, OPEN256.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, UNKNOWN277.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, UNKNOWN298.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, UNKNOWN316.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, UNKNOWN336 ft. AMH - Downstream Manhole, Survey Ends - 02 1794

Observation photos (1)

  • Lining Failure Blistered, from 06 to 08 o'clock, within 8 inches of joint: NO

    187.3 ft. - Lining Failure Blistered, from 06 to 08 o'clock, within 8 inches of joint: NO

Observations (19)

DistanceCodeObservation
126.3TFUNKNOWN, OPEN
234.8TFUNKNOWN, OPEN
0MGOLINED PIPE
118.2TFUNKNOWN, OPEN
186.8TFUNKNOWN, OPEN
336AMH02 1794
0AMH02 1795
187.3LFB
316.6TFOPEN, UNKNOWN
277.2TFOPEN, UNKNOWN
78.7TFCUNKNOWN, OPEN
256.4TFOPEN, UNKNOWN
75.5TFBUNKNOWN
298.2TFOPEN, UNKNOWN
207.6TFACTIVE
0MWL
162.7TFBUNKNOWN, OPEN
0MWM
122TBA

Properties (6)

additional_info
SC378660
custom_field_two
3
customer
LACSD
datetime
2019-10-11T03:00:20-07:00
documentation
PROPIPE
is_lateral_inspection
false