Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 12, 2019, 11:44 AM
  • 16 0307_16 0306 _11122019_040109.mp4

Date
11/12/2019
W/O
742114
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00665
PipeID
P13358
Time
3:44 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7118
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
21
Purpose
Routine Assessment
Project
WO_742114_TV16032_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
20 in.
Width
20 in.
Upstream MH
16 0307
Downstream MH
16 0306
Dir. of Survey
Downstream
Length Surveyed
315.7 ft.
Total Length
315.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
312L
O&M Rating
129
Overall Index
2
Overall Quick
Overall Rating
129
Pipe schematic from manhole 16 0307 to 16 0306
MH: 16 0307MH: 16 0306downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 6 O'CLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 16 03072 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start40.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"104 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"129.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"147.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"147.6 ft. RML - Roots Medium Lateral, from 08 to 11 o'clock, 15 %, within 8 inches of joint: YES178.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"196 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"232 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"280.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"285 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"310.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"314.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish314.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE315.7 ft. AMH - Downstream Manhole, Survey Ends - 16 0306

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Roots Medium Lateral, from 08 to 11 o'clock, 15 %, within 8 inches of joint: YES

    147.6 ft. - Roots Medium Lateral, from 08 to 11 o'clock, 15 %, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    314.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (21)

DistanceCodeObservation
129.5TFA
40.6TFA
0MGOACTIVE CONNECTION AT MH 6 O'CLOCK
232TFA
310.1TFC
314.7DAGS
147.6TFA
196TFA
280.2TFC
285TFA
84.1TFA
0MWM
2DAGS
315.7AMH16 0306
147.6RML
0MWL
0MGOCOCKROACHES IN MANHOLE
0AMH16 0307
178.4TFA
104TFA
314.7MGOCOCKROACHES IN MANHOLE

Properties (6)

additional_info
SC378749
custom_field_two
3
customer
LACSD
datetime
2019-11-12T03:44:45-08:00
documentation
PRO PIPE
is_lateral_inspection
false