Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 19, 2019, 05:58 AM
  • 05 1045_05 0115 _11182019_223107.mp4

Date
11/18/2019
W/O
792823
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00441
PipeID
P06280
Time
9:58 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7165
Sewer Name
05 FLOWER STREET TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_792823_TV05195_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 1045
Downstream MH
05 0115
Dir. of Survey
Downstream
Length Surveyed
334.8 ft.
Total Length
334.8 ft.
Structural Index
3
Structural Quick
5143
Structural Rating
24
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
31
Pipe schematic from manhole 05 1045 to 05 0115
MH: 05 1045MH: 05 0115downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 10450 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTIONS AT BOTH 3 AND 9 O'CLOCK IN MH2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.9 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"13.1 ft. BVV - Broken Void Visible, from 08 to 12 o'clock, within 8 inches of joint: YES14.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"54.8 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"74.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES84.8 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURED120.2 ft. MWLS - Water Level, Sag in pipe, 40 %of cross sectional area, Start126.5 ft. MWLS - Water Level, Sag in pipe, 40 %of cross sectional area, Finish127.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"139.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"141.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"156.5 ft. MWLS - Water Level, Sag in pipe, 45 %of cross sectional area, Start173.8 ft. MWLS - Water Level, Sag in pipe, 45 %of cross sectional area, Finish187.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES208.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"211 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"256.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"258.1 ft. FM - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES259.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"295.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"298.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"334.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish334.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish334.8 ft. AMH - Downstream Manhole, Survey Ends - 05 0115

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken Void Visible, from 08 to 12 o'clock, within 8 inches of joint: YES

    13.1 ft. - Broken Void Visible, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    54.8 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    74.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURED

    84.8 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURED

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    204.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    258.1 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

Observations (31)

DistanceCodeObservation
173.8MWLS
208.4TFC
156.5MWLS
3.9CM
141.9TF
127.4TFC
120.2MWLS
10.9TB
334.4CM
256.7TF
0AMH05 1045
139.2TFC
334.8AMH05 0115
211TF
74.4FM
0MWM
54.8TBI
258.1FM
295.9TF
2.3DAGS
14.7TFA
259.4TF
13.1BVV
187.3TF
0MWL
334.4DAGS
298.6TFC
84.8TFDFRACTURED
126.5MWLS
204.1FM
0MGOCONNECTIONS AT BOTH 3 AND 9 O'CLOCK IN MH

Properties (6)

additional_info
SC398405
custom_field_two
1
customer
LACSD
datetime
2019-11-18T21:58:17-08:00
documentation
PROPIPE
is_lateral_inspection
false