Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 20, 2019, 05:33 PM
  • 01 0743_01 0742_11202019_093536.mp4

Date
11/20/2019
W/O
0802827
Weather
Damp
Operator/Surveyor
FRANKLIN
Sewer ID
Z00205
PipeID
P01653
Time
9:33 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8137
Sewer Name
01 COMPTON DISPOSAL TRUNK
City
COMPTON
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
20
Purpose
Maintenance Related
Project
20191120DF_COMPTON_DISPOSAL_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
01 0743
Downstream MH
01 0742
Dir. of Survey
Downstream
Length Surveyed
378.7 ft.
Total Length
378.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 01 0743 to 01 0742
MH: 01 0743MH: 01 0742downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 9:34 AM0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 70% MAG92.5 ft. MGP - General Photograph172.1 ft. MGP - General Photograph206 ft. MGP - General Photograph376.3 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 80% MAG376.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish376.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish378 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)378 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach378.1 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active378.7 ft. AMH - Downstream Manhole, Survey Ends - 10:01 AM

Observation photos (7)

  • Upstream Manhole, Survey Begins - 9:34 AM

    0 ft. - Upstream Manhole, Survey Begins - 9:34 AM

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 70% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 70% MAG

  • General Photograph

    92.5 ft. - General Photograph

  • General Photograph

    172.1 ft. - General Photograph

  • General Photograph

    206 ft. - General Photograph

Observations (17)

DistanceCodeObservation
378MGOGREASE THROUGHOUT THE REACH (5%)
2SAP
376.3SZ80% MAG
92.5MGP
0MWL
172.1MGP
376.3SAP
378.1MGOConn. @ Mh, 3 O' Clock. Active
2SSS
0AMH9:34 AM
2SZ70% MAG
0MWM
206MGP
0MGOROACHES @ MH
378.7AMH10:01 AM
378MGOPeeling & Flaking Throughout The Reach
376.3SSS

Properties (6)

custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
LACSD
datetime
2019-11-20T09:33:22-08:00
documentation
FRANKLIN, RUVALCABA
is_lateral_inspection
false