- Date
- 11/26/2019
- W/O
- 0798461
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00444
- PipeID
- P06556
- Time
- 4:03 AM
- Certificate
- 1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0272
- Sewer Name
- 05 GARDENA PUMP TRUNK
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 21
- Purpose
- Capital Improvement Program Assesment
- Project
- 20191126_GARDENA_PUMP_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 17.209999084472656 in.
- Upstream MH
- 05 1339
- Downstream MH
- 05 1338
- Dir. of Survey
- Downstream
- Length Surveyed
- 305.1 ft.
- Total Length
- 305.1 ft.
- Structural Index
- 4
- Structural Quick
- 4100
- Structural Rating
- 4
- O&M Index
- 4
- O&M Quick
- 5244
- O&M Rating
- 35
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 39
Pipe schematic from manhole 05 1339 to 05 1338 Observation photos (8)

39.3 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start

47.7 ft. - General Photograph - 20% GREASE TOP OF PIPE

202.4 ft. - General Observation - 17.2" NRCP-CIPP

252 ft. - Lining Failure Other, from 12 to 03 o'clock, within 8 inches of joint: NO - POSSIBLE TEAR OR CRACK

252 ft. - General Photograph - POSSIBLE TEAR OR CRACK ON LINER

261.8 ft. - General Observation - UNUSAL SCRAPING MARKS ON LINER

272 ft. - General Observation - POSSIBLE LINER REPAIR OR TORN AREA-3:00

273.3 ft. - General Observation - POSSIBLE LINER REPAIR OR TORN AREA-3:00