Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 26, 2019, 10:41 AM
  • Section#2_05 1062_05 1061__11262019__I0271.mp4

Date
11/26/2019
W/O
0798048
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00488
PipeID
P06296
Time
2:41 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0271
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
20191126MDM_MONETA_EXTENSION_TRUNK_SECTION_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 1062
Downstream MH
05 1061
Dir. of Survey
Downstream
Length Surveyed
4 ft.
Total Length
4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 1062 to 05 1061
MH: 05 1062MH: 05 1061downstream0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:50AM0 ft. MWL - Water Level, 80 %of cross sectional area2 ft. MMC - Material Change, Vitrified clay pipe - PIPE IS NOT RCP2.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: NO - GREASE COAT ON PIPE4 ft. MSA - Survey Abandoned - DOWNLEG UPSTREAM SIPHON EAST

Observation photos (3)

  • Material Change, Vitrified clay pipe - PIPE IS NOT RCP

    2 ft. - Material Change, Vitrified clay pipe - PIPE IS NOT RCP

  • Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock,  , within 8 inches of joint: NO - GREASE COAT ON PIPE

    2.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: NO - GREASE COAT ON PIPE

  • Survey Abandoned - DOWNLEG UPSTREAM SIPHON EAST

    4 ft. - Survey Abandoned - DOWNLEG UPSTREAM SIPHON EAST

Observations (6)

DistanceCodeObservation
0MWM
2.9DAGSGREASE COAT ON PIPE
2MMCPIPE IS NOT RCP
4MSADOWNLEG UPSTREAM SIPHON EAST
0AMH2:50AM
0MWL

Properties (7)

additional_info
DOWNLEG UPSTREAM SIPHON EAST
custom_field_three
PIPE IS VCP NOT RCP-5% GREASE COAT ON PIPE
custom_field_two
4
customer
LACSD
datetime
2019-11-26T02:41:16-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false