Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 14, 2019, 05:16 AM
  • 05 0778_05 0777 _03132019_224310.mp4

Date
03/13/2019
W/O
755955
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00553
PipeID
P06006
Time
10:16 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6474
Sewer Name
05 MANCHESTER-VERMONT DIVERSION EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_755955_TV05272_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0778
Downstream MH
05 0777
Dir. of Survey
Downstream
Length Surveyed
394 ft.
Total Length
394 ft.
Structural Index
3
Structural Quick
514D
Structural Rating
498
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
498
Pipe schematic from manhole 05 0778 to 05 0777
MH: 05 0778MH: 05 0777downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 07782 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES9.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES14.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES15.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start122 ft. B - Broken, from 12 to 04 o'clock, within 8 inches of joint: YES122 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish126.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start389.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish392 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish392 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish394 ft. AMH - Downstream Manhole, Survey Ends - 05 0777

Observation photos (5)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    6.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    9.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    14.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    15.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 12 to 04 o'clock, within 8 inches of joint: YES

    122 ft. - Broken, from 12 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
0MWM
122B
0MWL
389.1FM
126.1FM
9.8FL
394AMH05 0777
6.1FM
392SSS
15.8FM
2SSS
14.1FM
0AMH05 0778
2CM
122FM
392CM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-03-13T22:16:37-07:00
documentation
PROPIPE
is_lateral_inspection
false