29 0099_29 0083 _08192019_015941.mp4
6.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
10.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
22.6 ft. - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES
22.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
75 ft. - Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: NO
88 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES
177.3 ft. - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES
177.7 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES
233.9 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 251.1 | DAGS | — |
| 126 | TF | — |
| 224.1 | TF | — |
| 99.2 | TF | — |
| 10.2 | FM | — |
| 221.9 | TF | — |
| 0 | AMH | 29 0083 |
| 72.5 | TF | — |
| 0.1 | MWM | — |
| 230.3 | TF | — |
| 252.2 | AMH | 29 0099 |
| 251.1 | CM | — |
| 22.6 | RFJ | — |
| 177.7 | FL | — |
| 173.4 | TFC | — |
| 0 | MGO | CONNECTIONS AT BOTH 3 AND 9 O'CLOCK AT MH |
| 233.9 | FM | — |
| 88 | FM | — |
| 22.6 | CM | — |
| 146.9 | TFA | — |
| 6.5 | DAGS | — |
| 75 | RML | — |
| 0 | MWL | — |
| 75.1 | TF | — |
| 177.3 | RFJ | — |