Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 8, 2019, 07:45 AM
  • C 0376C 0375 District 19_050819.mp4

Date
05/08/2019
W/O
761665
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00141
PipeID
P09839
Time
12:45 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6535
Sewer Name
C JOINT OUTFALL C - UNIT 8C
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_761665_TV19066_APR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
C 0376
Downstream MH
C 0375
Dir. of Survey
Downstream
Length Surveyed
376.2 ft.
Total Length
376.2 ft.
Structural Index
4
Structural Quick
5F3G
Structural Rating
302
O&M Index
4
O&M Quick
4421
O&M Rating
18
Overall Index
4
Overall Quick
Overall Rating
320
Pipe schematic from manhole C 0376 to C 0375
MH: C 0376MH: C 0375downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK0 ft. AMH - Upstream Manhole, Survey Begins - C 03760 ft. MWM - Water Mark, 50 %of cross sectional area6 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start8.1 ft. IR - Infiltration Runner, at 03 o'clock, within 8 inches of joint: YES29.1 ft. IR - Infiltration Runner, at 09 o'clock, within 8 inches of joint: YES71.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start71.2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish94.4 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES191.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"198.8 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start198.8 ft. HVV - Hole Void Visible, from 12 to 03 o'clock, within 8 inches of joint: YES198.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish216.6 ft. IR - Infiltration Runner, at 03 o'clock, within 8 inches of joint: YES303.8 ft. LR - Alignment Right, 15 %310.3 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start310.3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish338.6 ft. IS - Infiltration Stain, at 02 o'clock, within 8 inches of joint: YES374.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish376.2 ft. AMH - Downstream Manhole, Survey Ends - C 0375376.2 ft. MGO - General Observation - CONNECTION IN MH AT 3 OCLOCK

Observation photos (10)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Runner, at 03 o'clock, within 8 inches of joint: YES

    8.1 ft. - Infiltration Runner, at 03 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 09 o'clock, within 8 inches of joint: YES

    29.1 ft. - Infiltration Runner, at 09 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    71.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    94.4 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    198.8 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Hole Void Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

    198.8 ft. - Hole Void Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 03 o'clock, within 8 inches of joint: YES

    216.6 ft. - Infiltration Runner, at 03 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    310.3 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Stain, at 02 o'clock, within 8 inches of joint: YES

    338.6 ft. - Infiltration Stain, at 02 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
0MWL
310.3SAP
6SRV
376.2AMHC 0375
310.3SRV
216.6IR
71.2SAP
94.4SRV
374.2SAP
8.1IR
338.6IS
198.8SRV
29.1IR
0MGOCONNECTION IN MH 3 OCLOCK
198.8HVV
303.8LR
0AMHC 0376
198.8SAP
0MWM
71.2SRV
376.2MGOCONNECTION IN MH AT 3 OCLOCK
191.6TFA

Properties (6)

custom_field_two
1
customer
LACSD
datetime
2019-05-08T00:45:01-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26760