Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2018, 04:01 AM
  • _29 0461 _02102018_210851.mp4

Date
10/02/2018
W/O
729479
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00989
PipeID
P24505
Time
9:01 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6122
Sewer Name
29 LEWIS AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_729479_TV29059_OCT2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0461
Dir. of Survey
Upstream
Length Surveyed
359.7 ft.
Total Length
359.7 ft.
Structural Index
2
Structural Quick
3I2M
Structural Rating
298
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
300
Pipe schematic from manhole 29 0461 to unknown
MH: 29 0461MH: upstream0 ft. AEP - End of Pipe - 00.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"1.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"53 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"55.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN58.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN100.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish105 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"107.4 ft. RPP - Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: NO151.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN205.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN207.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN251.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - ACTIVE/BROKEN254.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"331.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6"334.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN334.4 ft. RPP - Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: YES350.8 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES357.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start357.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start359.7 ft. MWM - Water Mark, 5 %of cross sectional area359.7 ft. AMH - Downstream Manhole, Survey Begins - 29 0461359.7 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    8.9 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: YES

    25.3 ft. - Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: NO

    252.3 ft. - Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: NO

Observations (25)

DistanceCodeObservation
0MWM
25.3TFOPEN
252.3RPP
359.5TFC
304.1TFOPEN
25.3RPP
27.9TFA
205.1TFOPEN
154.5TFOPEN
2CM
358SSS
151.9TFOPEN
0AMH29 0461
301.4TFOPEN
359.7AEP0
2SSS
105.3TFC
356.7TFC
108.1TFDACTIVE/BROKEN
0MWL
306.7TFC
259.2CM
254.7TFC
8.9CM
207.9TFC

Properties (6)

additional_info
SC364842
custom_field_two
3
customer
LACSD
datetime
2018-10-02T21:01:59-07:00
documentation
PROPIPE
is_lateral_inspection
false