Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 26, 2019, 05:22 AM
  • 29 0340_29 0338 _03252019_225030.mp4

Date
03/25/2019
W/O
755793
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z01017
PipeID
P24360
Time
10:22 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6494
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_755793_TV29085_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0340
Downstream MH
29 0338
Dir. of Survey
Downstream
Length Surveyed
250.2 ft.
Total Length
250.2 ft.
Structural Index
2
Structural Quick
5146
Structural Rating
139
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
139
Pipe schematic from manhole 29 0340 to 29 0338
MH: 29 0340MH: 29 0338downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 03400 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - ROACHES @ MH13.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES14 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"27.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"35.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"54.1 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES65.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"66 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES78.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES94.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"114.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"141.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"154.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"157 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish164.4 ft. B - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES165.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"168.4 ft. FM - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES179.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES185.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start209.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"212.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"248 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish249.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish250.2 ft. AMH - Downstream Manhole, Survey Ends - 29 0338

Observation photos (9)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    13.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    54.1 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    66 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    78.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

    164.4 ft. - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    168.4 ft. - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    179.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    185.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (29)

DistanceCodeObservation
157CM
78.2CM
0AMH29 0340
249.1FM
54.1FM
209.5TFC
13.2FM
0MWL
27.2TFA
141.2TFA
2SSS
250.2AMH29 0338
248SSS
165.2TFC
14TFC
2CM
179.3FM
168.4FM
0MWM
66CM
164.4B
212.6TFC
65.1TFC
2MGOROACHES @ MH
154.9TFC
94.3TBA
114.4TFC
185.2FM
35.4TFC

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-03-25T22:22:30-07:00
documentation
PROPIPE
is_lateral_inspection
false